Use Modifiers
    • 20 Jun 2024
    • 1 Minute to read
    • Contributors
    • PDF

    Use Modifiers

    • PDF

    Article summary

    In a form, modifiers, database commands, scripts and XML Transformer forms can be connected to the following types of event points:

    • Form

    • Sheet

    • Page (only for the EMF, TIFF, PDF output sheet types)

    You can access and manage form modifiers for all sheets available in the application from the main menu Lasernet Developer > Form > Modifiers:

    When processing a form, the modifiers, database commands, scripts or XML Transformer forms are run in the following order:

    Form Start modifier point:

    Sheet Start modifier point

    Definition of all JobInfos contained in the sheet

    Sheet Before Script modifier point

    NumberOfPages JobInfo contains the number of pages in the document produced

    CurrentPage JobInfo is updated*

    Page Start modifier point*

    Rearrange scripts in the Conditional Area*

    Page End modifier point*

    Scripts attached to rearranges

    Sheet After Analysis modifier point

    Sheet End modifier point

    Note

    Steps marked with an asterisk (*) are repeated for each page.

    Form End modifier point:


    What's Next