Error Message: ‘The Menu Item with Name Lactestuxloadrunredirect Could not Be Opened’ When Running the UX Test Scenario
    • 11 Nov 2024
    • 1 Minute to read
    • Contributors
    • PDF

    Error Message: ‘The Menu Item with Name Lactestuxloadrunredirect Could not Be Opened’ When Running the UX Test Scenario

    • PDF

    Article summary

    Issue

    When attempting to run a UX test scenario, the following error message appears:

    Error

    The menu item with name lactestuxloadrunredirect could not be opened.

    This error prevents the UX test from running.

    Causes

    A UX test error can occur due to two reasons:

    • In versions older than 6.20.0.2, if the Title/recording name field contains too many characters, this can cause the field to remain blank. Standard Dynamics 365 FO has a character limit of 80 characters.

    • The error can occur due to user system access, namely, if the user tries to run the task but does not have the correct access rights.

    Solution

    To solve the issue, ensure the UX test recording exists by clicking Task recordings to open the full list.

    If the recording exists, try the following solutions:

    • If the Title/recording name field contains too many characters, upgrading to version 6.20.0.2 or newer will automatically cut off the number of characters that can be entered in this field.

    • If the issue concerns security access, giving a user the roles of Lasernet administrator, Lasernet advanced user, or system administrator will grant the user access to run the UX test.


    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.