- Print
- PDF
A Test checkpoint defines a single report test setup.
The following settings are needed on the report to create and use a Test checkpoint:
Set Archive to Default or Manual to archive a report. This setting is used to archive the report.
Set the Save XML toggle button to Yes. The XML file is saved for comparing the Test checkpoint with the test result.
Do not leave the Table for archive field blank, otherwise, you will get the following error when creating a Test checkpoint for the report:
Error
Checkpoint archive does not have linked reference record. Make sure that report has 'Table for archive' set and that archive used for checkpoint has reference record to it.
Do not leave the Resend menu item blank, otherwise, you will get the following error message when running a test and using Force rerun:
Error
No object specified on menu item
If you are using a custom Lasernet Query (not a replacement Lasernet Query), set this to LACRunController.
Example Setup for the SalesConfirmReplacement Replacement Report
Archive set to Default.
Save XML set to Yes.
Table for archive set to CustConfirmJour in this example, but this may vary depending on the Query you are using.
Resend menu item set to SalesConfirmation in this example, but this may vary depending on the SSRS report being replaced.
Example Setup for a Custom Lasernet Query that Uses the CustTable in the Query
Archive set to Default.
Save XML set to Yes.
Table for archive set to CustTable in this example, but this may vary depending on the custom Query you are using.
Resend menu item set to LACRunController.
Create a Test Checkpoint
A Test checkpoint can be created once a report has been run and an archive record has been created. A Test checkpoint can be created from:
The Lasernet report form
The Lasernet Archive
Create a Test Checkpoint from the Lasernet Report
Follow these steps:
Navigate to Lasernet > Common > Reports.
Select a report, and then click Testing > New checkpoint.
This will open a form displaying a record for the last time that this report was archived. In this example, the PurchPurchaseOrderReplacement was last archived:
On 15/07/2024 at 11:25:46
Run by Admin
Printed to Screen
This data can be used to check that you are creating a Test checkpoint for the correct archived report run. The Checkpoint and Description fields are predefined for you. However, these can be changed if needed.
Click Create to create a Test checkpoint for this report run.
The Test checkpoint form will automatically open once the Test checkpoint is created. Here is the Test checkpoint record in the Test checkpoint form:
Create a Test Checkpoint from the Archive
Follow these steps:
Navigate to Lasernet > Common > Archive.
Select an Archive record, and then click Testing > New checkpoint.
This will open a form displaying a record for this report run. In this example, the PurchPurchaseOrderReplacement was run:
On 27/06/2024 at 15:14:42
Run by Admin
Printed to Screen
This data can be used to check that you are creating a Test checkpoint for the correct archived report run. The Checkpoint and Description fields are predefined for you. However, these can be changed if needed.
Click Create to create a Test checkpoint for this report run.
The Test checkpoint form will automatically open once the Test checkpoint is created. Here is the Test checkpoint record in the Test checkpoint form:
Test Checkpoints in the Archive
Navigate to Lasernet > Common > Archive.
Test checkpoints can be easily identified in the Lasernet Archive, as they are marked in yellow: